Using the Visual Studio 6.0 Driver Build Environment Tulsa OK

This article explores how to use the standard Visual Studio environment while developing device drivers.

Local Companies

Griffey & Associates
918-627-6399
5350 E 46th Street Suite 145
Tulsa, OK
B Solutions LLC
918-749-9200
5645 S Madison Ave
Tulsa, OK
Software House International
918-583-4182
307 W Young St
Tulsa, OK
Software Etc
918-254-9124
Woodland Hills Mall
Tulsa, OK
Axis Integrated Solutions
918-488-1881
2818 E 81st Pl
Tulsa, OK
Oaktree Software Inc
918-584-7900
1437 S Boulder Ave
Tulsa, OK
Anyware Mobile Solutions
918-280-8693
5800 E Skelly DR
Tulsa, OK
Personal Computer Services
918-665-6229
PO Box 470302
Tulsa, OK
Dreyer Software Inc
918-838-7638
PO Box 3391
Tulsa, OK
Computer Software Solutions
918-627-1117
9717 E 42nd St
Tulsa, OK

provided by: 
Originally published at Internet.com


I've already borrowed so much information from CodeGuru that I've started getting frustrated that I haven't contributed anything myself to the site. Therefore, I respectfully offer this articles to my fellow programmers.

Some time ago, I had to write an NT 4.0 device driver. Since I was already used to the comfort of Visual Studio 6, it was hard to me to fall back to the free build and checked build environments, provided by the DDK. Especially I missed the browser possibilities that Visual Studio provides.

So, I started around digging into the DDK build environment to find out how it works, and if I could extend the environment to be usable within the Visual Studio. My primary goal was to keep the existing environment intact, and furthermore, I want to use this environment within VS 6.

The solution was simpler than I expected. I only need to set up some additional files.

_build.bat

. This *.bat is directly called by VS 6 and has the same command parameters as the DDK setenv.bat. This *.bat will clean up some existing files ( i.e. build.dat which I do wish to rebuild every time ), saves the actual directory ( see PrCHDIR ) and calls the original setenv.bat from the DDK. The _build.bat calls bscmake.exe at the end. This enables me to browse to the source code afterwards. The _build.bat is not project-depended.

PrCDIR.exe

On starting setenv.bat, one is move into the DDK root directory. And this not so good if you want to automate the environment. The small PrCHDIR program prints the actual directory and drive letter. The _build.bat catches it output and stores it into a @temp.bat. Once the setenv.bat has been called, the @temp.bat puts you back into your proper build directory.

I386mk.inc

The DDK build environment use this file which resides in the %DDKROOT%\Inc directory. If you copy this file into your proper build directory, the Build will use this file instead. I extended this file with following lines: !IF "$(ASM_LST)"=="YES" DBGFLAGS=$(DBGFLAGS) /FAcs /Fa$(TARGETPATH)\$(TARGET_DIRECTORY)\$(TARGETNAME).asm !ENDIF !IF "$(GEN_SBR)"=="YES" DBGFLAGS=$(DBGFLAGS) /FR$(TARGETPATH)\$(TARGET_DIRECTORY)\$(TARGETNAME).sbr !END ...

Read article at Internet.com site

Featured Local Company

Oaktree Software Inc

918-584-7900
1437 S Boulder Ave
Tulsa, OK
http://www.oaktreesoftware.com


Topics: 
Architecture & Design Languages & Tools Project Management Web Services
Database Microsoft & .NET Security Wireless
Java Open Source Techniques XML